Consulting Room Equipment

To place an order on any of the consulting room equipment below from within Australia, or to make an inquiry about any device/s not listed, please Contact Medmont


Frastema Simplex 2Frastema Simplex

Space saver and refraction quality all in one. Chair stand and controls are mounted on a weighted base available for refracting with maximum dimension (1250x1300 mm only).

This unit is designed for ultimate patient comfort and is a time-saver in instrument handling during refraction.



Neitz Halogen OphthalmoscopeNeitz Halogen Ophthalmoscope

Polarized Filter
While observing fundus through the ophthalmoscope, you can insert polarising filters both in the illumination and observation axes. By this way, corneal reflex is minimised while maintaining observation. The polarizing filter in the observation axis can be rotated so that an optimum balance between brightness of visual field and amount of corneal reflex may be achieved.

Bright Illumination
The combination of an effective condensing lens and mirror reflection system makes the best use of brilliant halogen light source.

Wide Range of Corrective Lenses 
Corrective powers range from -36D to +35D in 1D steps, ensuring the sharpest focus of fundus image at all times. The corrective lens wheel is rotatable endlessly, allowing smooth change of powers even when the amount of change is great.

Direct Reading Diopter Indicator 
The diopter of the corrective lens is indicated directly even when using high plus or minus power so that the need to add or subtract the power of auxiliary lens may be eliminated. The diopter indicator is illuminated from inside, making it possible to read the powers clearly even in the dark room.  

Separate Operation for Aperture Dial and Filter Lever  
The aperture dial and the filter lever are moved separately so that all apertures can be used with a 4000ºK filter or a polarising filter.

Aperture Dial  
The aperture dial contains a standard aperture, a small aperture for macula observation, as slit aperture, a concentric scale aperture and a red-free filter aperture.
Filter Lever  
With a flip of the filter lever, the 4000ºK filter and the polarizing filter can be selected.
Aperture Shutter  
All optical systems are totally enclosed in the instrument head. When not in use, the aperture shutter prevents dust from infiltrating the head.

Back to Top


Neitz Streak RetinoscopeNeitz Streak Retinoscope

Bright and Wide visual field
The reflection-free filter gives a brighter and wider field of vision, resulting in less fatigue even after long time use.

Easy to operate
It has a separate control for streak width and streak rotation. Streak width neve changes while rotating. The entire head is rotatable so that you can easily choose the best position to use. It is compact and light.

Endless Rotation  
The streak revolves 360 degrees without stops (except RX-1), enabling quick measurement of astigmatic axis.
The built-in head rest prevents the operator's spectacles from getting scratched.
The presbyopic +2D lens is easily fitted into the aperture in the head.
Standard Equipment: +2D Presbyopic lens, Optional: +3D and +1D presbyopic lenses.

Back to Top


Neitz IO-Alpha Halogen Binocular Indirect Ophthalmoscope IO-Alpha

A. Illumination Angle Adjustment Knob, for adjustment of illumination angle according to the size of pupils.

B. Observation Angle adjustment Knob. Observation Angle can be adjusted for either small or dilated pupils.

C. Filter Change Lever. UV, blue and red-free filters can be changed.

D. Aperture Change Lever. 3 different lighting areas of Ø19mm, Ø50mm, Ø80mm can be selected.

Outstanding Features:

  • Fundus image can be observed stereoscopically even through a small pupil of 2mm diameter without dilation.
  • Observation angle can be continuously changed, which allows you to observe the fundus from any desired angle.
  • The built-in halogen light provides illumination closely resembling natural sunlight.
  • Designed for easy operation. The mirror moves smoothly, and the power cable from the transformer can be connected to either side of the headband, for a right or left-handed observer.
  • Transformer can be either wall mounted or placed on the desk.
  • Contains UV, BLUE, RED-FREE Filters inside, which can easily be changed with the filter change lever. Ideal for observing various symptoms.

Back to Top


Neitz IO-Alpha TV Binocular Indirect OphthlmoscopeIO-Alpha TV

  • CCD Camera
  • Non-mirror image on monitor screen. Focusing by remote control. IO-AlphaTV is the combination of highly sophisticated BIO and high resolution CCD camera (NTSC 410,000 pixel / PAL 470,000 pixel) that can provide a NON-MIRROR image of what the examiner is observing on monitor screen. Remote control focusing system facilitates focusing operation greatly. Observation of fundus through Small Pupil of 2mm in diameter is possible.
  • Highly Sophisticated BIO (small pupil) combined with High Resolution CCD Camera that can provide a very clear image of what the examiner is observing on monitor screen.
  • Easy setup, the control section and power supply section are combined in one box, and the setup is very simple and easy.
  • Connection to video peripherals. The system comes with video signal output terminal for connection to video peripherals such as TV monitor, video printer, VCR, etc.

Back to Top


Neitz Binocular Loupes - BLP-4/BLP-6 (X4/X6)Binocular Loupes

BLP-4 and BLP-6 employ Keplerian optical system and can provide breath-takingly sharp and clear image from edge to edge. Very light (BLP-4/6 : 84g/88g). Frame adjustment is easy due to employment of titanium frame.
BLP-4 and BLP-6 offer good flexibility as everything is adjustable in these loupes.

Focus Distance is adjustable:
BLP-4/6 come with Focus Distance Adjustment Ring that enables changing of work distance by rotating the Ring clockwise/anti-clockwise. This is convenient when a user wants to use the same loupe on various occasions. The function also enables nearsighted or farsighted users to use the loupe without having glasses in frame. (Extremely advanced myopia and hyperopia may necessitate use of glasses.)

Back to Top


Neitz Auto Contacto-Guage (CG-Auto)CGA2

  • Automatic Measuring of Base Curve. Neitz CG AUTO is the automatic radiuscope with which highly accurate and repeatable measurement of base curve of contact lens can be done simply by placing lens on lens seat and pressing START switch.
  • Measuring results are available within 10 seconds.

No alignment is required. Focusing is done automatically.

  • The equipment can decrease dependence on human skills, leading to objective measuring and elimination of discrepancies among operators, something essential to products' conformity to International Standards.
  • CG AUTO can also check lens surface quality as well as degree of toricity (difference between X and Y axis values) while measuring base curve.
  • Measuring of CL centre thickness is also possible (optional).
  • CG AUTO is available in two versions:
              1. CG AUTO (standard) for measuring of finished CLs
              2. CG AUTO PLUS for measuring of semi-finished buttons

Back to Top

Monday, May 25, 2009, Administrator


Powered by umbraco